clinitek status urine analyzer manual

File Name:clinitek status urine analyzer manual.pdf
Size:3832 KB
Type:PDF, ePub, eBook, fb2, mobi, txt, doc, rtf, djvu
Category:Book
Uploaded15 May 2019, 21:33 PM
InterfaceEnglish
Rating4.6/5 from 594 votes
StatusAVAILABLE
Last checked7 Minutes ago!

clinitek status urine analyzer manual

Together, these provide improved clinical information. Trimark Publications.Would you like to provide detailed feedback. Sign in Forgot Password. My Bench Close Sign In Not A Member. Sign Up Join MedWrench OK name type Receive Summary Emails. Studies have shown that when urinalysis is performed with an instrument, sensitivity is increased and positives are correctly identified and reported. FORUMS View All (6) Ask a New Question 1 Reply -ARJ 5 years ago 5 years ago Need Service Manual By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details. All Rights Reserved. Precept and Cidex are. The analyzer automatically checks each test strip for humidity exposure. Clinitek Status Analyzer. 3. Specimen collection container. 4. Paper towels. Principle of the Test: Siemens Reagent Strips for urinalysis are read instrumentally. 14 Aug 2009. Principle and procedure for the Clinitek Status. Automated analyzer. Answers for Need Service Manualquestions on MedWrench. Page 1. Siemens - CLINITEK Status AnalyzerLook no Further, In today s busy physician s office environment, interruptions are frequent and can contribute to timing error. Clinitek, Clinitek Status, Clinitest, and Chek-Stix are trademarks of Siemens. If the Clinitek Status Connect system is used in a manner differently from that. 1. Scope. This Standard Operating Procedure (SOP) applies to the staff and students using the. The Clinitek Status analyser is even easier to use and offers the broadest menu available on any point of care automated Clinitek urine analyser. Clinitek Status. 5. NY 10591-5097 USA Bayer Diagnostics Mfg (Sudbury) Ltd Sudbury. US Pats 5. D456. Bayer HealthCare continues to improve products and. Siemens POCkit is an education solution for point-of-care testing.Reload to refresh your session. Reload to refresh your session. Discover everything Scribd has to offer, including books and audiobooks from major publishers.

Start Free Trial Cancel anytime. Report this Document Download Now Save Save clinitek-status-plus-operator-manual.pdf For Later 0 ratings 0% found this document useful (0 votes) 406 views 144 pages clinitek-status-plus-operator-manual.pdf Uploaded by Estie Kiriwenno Description: Full description Save Save clinitek-status-plus-operator-manual.pdf For Later 0% 0% found this document useful, Mark this document as useful 0% 0% found this document not useful, Mark this document as not useful Embed Share Print Download Now Jump to Page You are on page 1 of 144 Search inside document Browse Books Site Directory Site Language: English Change Language English Change Language. The analyzer automatically checks each test strip for humidity exposure, common sample interferences and strip identification for Siemens test strips. Together, these provide improved clinical information.Be the first to write a review Website Design and SEO by MedResponsiveWebsite Design and SEO by MedResponsive. Here are the instructions how to enable JavaScript in your web browser.Together, these provide improved clinical information.All rights reserved. Together, these provide improved clinical information. Together, these provide improved clinical information. June 12, 2009 For full details refer to “Conditions of Supply of Product for Professional Use (Healthcare)” Some substances can interfere with patient results. If this is evident, or if test results are questionable or inconsistent with expected ?ndings, con?rm that the product is within its expiration date and is reacting properly using known negative and positive control materials.These substances include visible levels of blood or bilirubin and drugs containing dyes, nitrofurantoin, or ribo?avin. Levels of ascorbic acid normally found in urine do not interfere with these tests. Mix the sample before testing and test it within two hours after voiding, sooner if testing for bilirubin or urobilinogen.

Contamination of the urine specimen with skin cleansers containing chlorhexidine may affect protein (and to a lesser extent speci?c gravity and bilirubin) test results. Work areas and specimen containers should always be free of detergents and other contaminating substances. If unable to test within the recommended time, refrigerate the specimen immediately and let it return to room temperature before testing. It requires 6 alkaline AA-size batteries. For example, a trace protein result with a high SG reading may well be normal, while trace protein with low SG is usually abnormal. For labels, each unit size contains 5 x 10.7m rolls (53.5m total). The number of result printouts depends on the strip type used. This works out to approximately 174 printouts per paper roll (870 total), and approximately 87 printouts per label roll (435). Both are thermal paper however the difference is the printer label has an adhesive backing which provides for direct attachment to patient notes without the need to use tape. Printer paper requires tape to be used if attaching to patient notes. Colour changes that occur after 2 minutes are of no diagnostic value. Quality control testing also detects errors resulting from incorrect user technique. Where only one QC sample is tested, it should have a concentration in the clinically relevant range for the analyte being measured.Do not use tap water or Sterile Water for Injections. Place the strip into the tube of water. Gently invert the tube(s) back and forth for 2 minutes. Allow the tube(s) to stand for 30 minutes at room temperature.Ketone reactivity in the Positive Control will increase with time due to continued hydrolysis of the reactive ingredient. Through this customisable approach, individual learners can plan, achieve, and maintain proficiency standards directly from any device at their convenience. Contact Us to Register Your Interest Already a member.

Each section of the service manual is dedicated to specific areas of interest: General features, methods overview, troubleshooting, error code descriptions, repair, functional diagrams, and parts breakdown. NEXT Page 3 INTRODUCTION AND GENERAL DESCRIPTION 3 OF 8 1.2 Features The major feature is the lower cost and size, portability, centered around small office placement, converting from visual user to instrument. COMPUTER INTERFACE: 9-Pin RS-232 protocol with comma deliminated output. Null modem cable required. NEXT Page 7 INTRODUCTION AND GENERAL DESCRIPTION 7 OF 8 PRINTER PAPER: (Ludlow C-696) Width — 5.8 cm (2.28 in.) Length — 2500 cm (82 ft.) Shelf Life — 5 years Storage — DEFAULT SETTINGS: Default settings are defined in the Operator’s Manual. New instruments are shipped from the manufacture set to English-Conventional. A series of six light emitting diodes (LED) each at a different wavelength illuminates the entire strip or cassette length. Reflected light from the strip is then passed through a lens and focused on a photodiode detector array (CCD) which then converts the light energy into an electronic signal. Once there, the signal is processed into percent reflectances and then decodes. These decode values are compared to lookup tables containing specific decode ranges for each reagent and their respective clinical values. For methods used on the urine reagent strips and immunoassay cassettes, refer to their specific product inserts. This section describes both strip and cassette test procedures. The procedures to enter the Operator and Patient data are presented in this section. The strip testing process is identical to a Quick Strip Test. Testing is started from the main Select screen. Touch Strip Test to conduct a Bayer urinalysis strip test. The next screen that appears is Operator ID. If you are this operator, then touch the Last Operator button to proceed.

OPTION 2: ENTER NEW OPERATOR ID In order to enter the information for a new operator, touch Enter New Operator ID button. The next screen that is displayed is Enter Operator ID. Touch Enter when you have finished entering the ID and to move to the next screen. The next screen displayed is Patient Information. There are two options under Patient Information: Recall Patient or Enter New Patient. If previous patient identification has been entered, a list of up to 200 patient results will appear on the screen. Use the up and down arrow buttons to scroll through the list of patients. The most recently performed test will be shown at the top. Once the patient is highlighted, touch Select button. The next screen will be Prepare Test. NOTE: A total of 200 patient tests can be stored in the analyzer. The tests are listed in chronological order. When the limit of 200 has been reached, the oldest test will be deleted from the analyzer. Deleted information cannot be retrieved from the analyzer. The next screen displayed is Enter Patient Name. Use the keyboards to enter Patient Name using a maximum of 20 characters. Touch Enter when you have finished entering the patient’s name and to proceed to the next screen. The next screen that appears is Prepare Test. While the strip is being analyzed, a Select Appearance screen will be displayed. The urine sample must be visually observed and then the appropriate color and clarity must be selected. If the urine sample is not yellow and clear, touch the Other button for more choices. If you touched the Other button, then select the appropriate color by touching the circle button that corresponds to the correct description. Then touch Next. There is a time indicator on the Select Appearance screen that is counting down the time remaining in the analysis of the strip. The procedures to enter the Operator and Patient data are presented in this section. The cassette testing process is identical to a Quick Cassette Test.

Testing is started from the main Select screen. Touch Cassette Test to conduct an hCG pregnancy test. There are two options under Operator ID: Last Operator or Enter New Operator ID. If you are this operator, then touch the Last Operator button to proceed. OPTION 2: ENTER NEW OPERATOR ID In order to enter the information for a new operator, touch Enter New Operator ID button. The next screen that is displayed is Enter Operator ID. One of our dedicated account managers will reach out to you with your pricing and to discuss your logistics needs within 12 hours. For information on a similar product or replacement please call us at (800) 338-2372. The analyzer automatically checks each strip for humidity exposure and identifies Siemens test strips. Together, these provide improved clinical information. June 12, 2009. Together, these provide improved clinical information. Together, these provide improved clinical information. Very sturdy and ergonimic, would purchase again!Glad I got this. Most reliable Opthalmoscope available. Speedy service!Please state how many units you require and how much you wish to pay per unit, excluding VAT. RAPIDComm 3.0 also allows for remote downloading of operator information, eliminating the need to manually add or delete operators from individual analyzers. RAPIDComm Data Management and Connectivity Solution Version 3.0 is a proprietary Siemens solution for monitoring point-of-care urinalysis and blood gas systems. Siemens' RAPIDSystems family of blood analyzers offers a comprehensive portfolio in critical care testing, delivering results near a patient's bedside or supporting the demands of high throughput in a clinical laboratory. CLINITEK is the most widely used urinalysis brand worldwide. The Siemens Healthcare Sector is one of the world's largest suppliers to the healthcare industry and a trendsetter in medical imaging, laboratory diagnostics, medical information technology and hearing aids.

Siemens offers its customers products and solutions for the entire range of patient care from a single source - from prevention and early detection to diagnosis, and on to treatment and aftercare. By optimizing clinical workflows for the most common diseases, Siemens also makes healthcare faster, better and more cost-effective. Siemens Healthcare employs some 48,000 employees worldwide and operates around the world.If you have an enquiry, please use the contact form below the article or company profile and we will send your request to the supplier so that they can contact you directly. The analyzer also saves clinicians valuable time by automatically identifying the type of urine test strip it is evaluating, eliminating manual entry of this information. The system also offers increased testing oversight capabilities by storing up to 700 operator IDs that can be programmed with varying levels of system access, preventing unauthorized use of the system. Operator and patient identification, as well as lot and expiration dates, are transmitted with test results to improve risk management of urinalysis test reporting. Additionally, the CLINITEK Status Connect System enhances quality control (QC) management capabilities by allowing test lockout if quality controls fail or are not performed. “These CLINITEK innovations offer next-generation quality checks and automation capabilities to help clinicians achieve even greater levels of efficiency and accuracy in urinalysis testing,” said Hanjoon Ryu, Senior Vice President, Point of Care, Siemens Healthcare Diagnostics. “We will continue to work closely with physicians and laboratories to create industry-defining innovations for point of care testing.” CLINITEK is the most widely used urinalysis brand worldwide with customers purchasing over 65,000 CLINITEK Status Analyzers since 2003.

The company is a renowned medical solutions provider with core competence and innovative strength in diagnostic and therapeutic technologies as well as in knowledge engineering, including information technology and system integration. With its laboratory diagnostics acquisitions, Siemens Healthcare is the first integrated healthcare company, bringing together imaging and lab diagnostics, therapy, and healthcare information technology solutions, supplemented by consulting and support services. Additionally, Siemens Healthcare is the global market leader in innovative hearing instruments. The company employs around 49,000 people worldwide and operates in 130 countries.The industry leaders have already defined that empowering processes is the way out to keep up with the changing landscape of global healthcare needs.Designed by Leo Marcom Pvt.Ltd. By continuing to use this site you consent to the use of cookies, unless disabled from your browser. Ok Cookie Policy. I prev next out of 4 Post on 11-Feb-2018 249 views Category: Documents 10 download Report Download Facebook Twitter E-Mail LinkedIn Pinterest Embed Size (px)Siemens CLINITEK Status Plus Analyzer no manualtranscription needed, Routine urinalysis with CLINITEKMultistix urine test strips. Additionally, the Clinitek Status, and Aution 11and Aution Micro, can also measure When comparing the Urisys analyser to manual examinationof the urine. When I turned the dryer Clinitek Status Plus Analyzer Manual.Leave a Comment! The analyzer features a built-in thermal recorder andindividual parameters can be Para 12 Plus Retics 12-way or 8-waymanifold, automatic and manual positioning Advantus, Clinitek Status,Clinitek Status Plus for the components.The CardioChek Plus Analyzer Includes: 1Meter, 1 Professional User Manual, 1 Professional Quick ReferenceGuide, CLINITEK Status and Multistix are registered trademarks.Lot: see FSN attachment.

MD: Manual orthopaedic bender, reusableHemosIL PT Fibrinogen HS PLUS Tosoh Automated GlycohemoglobinAnalyzer. IVD: Glycated CLINITEK Status Power Supply Adapter(Spare part) Model see FSN. status. If your MTS is located in a facilityaccredited by the Joint Commission, you have the option Differentialsare counted as one test. Table Status Test Clinitek Ea (1085968). Plus, the damn thing wasn't interfaced so I had to manually input resultsanyway.:( I much preferred the bench I rarely saw the techs use it,again, sometimes manual is much much faster.We also do pcrtests. UA: Clinitek Status. A New HomePaired with a CLINITEK Status Connect analyzer, the CLINITESThCG test provides the only truly connected, Since no manualdocumentation or visual. BAYER clinitek ATLAS Clinitek 200 Plus UrineChemistry Analyzer If it is not.Clinitek Status Operator Manual Clinitek Status Pregnancy Testing Training Plan Clinitek Status Pregnancy Testing CompetencyAssessment Standard Operating Procedures and CompetencyAssessments Roche coaguchek XS Plus. Activated Partial Thromboplastin Time (APTT) byautomation as well as manual method., Elecsys Biochemistry Analyzer, Beckman Synchron CX3, CX5, CX7, Clinitek Status, Clinitek 500,for Urine Examination. Observe all warning and hazard statements. Convention Description Biohazard statements alert you to potentially biohazardous conditions. Italic type refers to the title of a document, Italic a section title in this guide, or screen name. Clinitek Status Connect System Operator’s Guide. The Clinitek Status connector and Clinitek Status analyzer together are the Clinitek Status Connect system. This Operator’s Guide provides information on setting up and using functionality provided by the connector. For complete information on using the analyzer, refer to the Clinitek Status Analyzer Operator’s Manual. You cannot import data from a spreadsheet into the system. NOTE: Clinitek Status Connect System Operator’s Guide.

For complete information on using the analyzer, refer to the Clinitek Status Analyzer Operator’s Manual. Analyzer Overview This section provides a quick reference on navigating and using the analyzer user interface screens, entering information, test modes, and setting the password. For more information on Operator IDs, refer to Managing Operators List. Clinitek Status Connect System Operator’s Guide. For unpacking and installation instructions, see System Configuration. If there is no connector, Siemens recommends setting the connector to NOTE: Disabled setting. Setting the connector to the Enabled setting without a connector may prevent communication with an external system. Clinitek Status Connect System Operator’s Guide. If you selected Disabled, select Done 3 times to return to the Select Ready screen. Clinitek Status Connect System Operator’s Guide. If you delete the entire operator list, ensure that authorized operators is NOTE: Disabled. See Setting Operator IDs above. Clinitek Status Connect System Operator’s Guide. To permit entry of patient information by either bar code scanner or manually, select Disabled. Clinitek Status Connect System Operator’s Guide. The Input Settings-Confirmation screen displays. 13. Select Done twice to return to the Select Ready screen. Clinitek Status Connect System Operator’s Guide. You can select only one color for a urine sample. NOTE: Clinitek Status Connect System Operator’s Guide. To enter new strip data, select Enter new lot and expiration. The Strip Lot screen displays. Clinitek Status Connect System Operator’s Guide. Clinitek Status Connect System Operator’s Guide. You can set the instrument to lock out testing any patient sample until all QC control results are within the acceptable range. If a control result is out of Clinitek Status Connect System Operator’s Guide. To have the operator determine QC pass or fail, select Operator. Clinitek Status Connect System Operator’s Guide.

The QC Strip Type-Select strip for this QC level screen displays. 10. Use the arrow keys to select the strip type. 11. Select Select. The Control Level 1-Strip test screen displays. Clinitek Status Connect System Operator’s Guide. The QC Settings-Set QC time for strip tests screen displays. Clinitek Status Connect System Operator’s Guide. To permit patient tests even if a QC test is due, select Reminder. 3. Select Next. The QC Settings-Cassette test screen 2 of 3 displays. Clinitek Status Connect System Operator’s Guide. Clinitek Status Connect System Operator’s Guide. To enter numeric text, select 123. 13. Select Enter. The Strip Expiration screen displays. Clinitek Status Connect System Operator’s Guide. To enter numeric text, select 123. 5. Select Enter. The Enter Control Level screen displays. 6. Enter the control level. Use the alpha keyboard to enter text. To enter numeric text, select 123. Clinitek Status Connect System Operator’s Guide. Managing QC Results This section describes how to add notes to QC test results and print QC strip or cassette results. Clinitek Status Connect System Operator’s Guide. If fresh solution fails to give results within the expected values, proceed to the next possible cause. Clinitek Status Connect System Operator’s Guide. Check the calibration bar for dust, dirt, or scratch marks, or contact your local technical support provider for assistance. Clinitek Status Connect System Operator’s Guide. It is not possible to copy Set Up. The software versions do not match. The software versions detected are not compatible. Install new software or notify your local representative. Clinitek Status Connect System Operator’s Guide. To enter numeric text, select 123. 8. Select Enter. Go to Step 11. 9. Use the arrow keys to indicate the date range. 10. Select Search. The Recall Results-Search Results screen displays. Clinitek Status Connect System Operator’s Guide. Select No to return to the Recall Options screen. 5.

Select Done to return to the Select Ready screen. Clinitek Status Connect System Operator’s Guide. Place the Clinitek Status Connect system where it will avoid extreme temperature variations. Avoid proximity to open windows, direct sunlight, ovens, hot plates, open burners, radiators, and dry ice baths. Do not place the system on the same bench as a source of vibration. CAUTION Use caution if moving the system, as the two units will not be securely attached and may separate. Clinitek Status Connect System Operator’s Guide. Clinitek Status Connect System Operator’s Guide. The Choose Settings screen displays. 2. Use the arrow keys to select Instrument Settings. 3. Select Select. The Instrument Settings screen displays. Clinitek Status Connect System Operator’s Guide. Clinitek Status Connect System Operator’s Guide. For additional information, refer to the Clinitek Status LIS Specification. Clinitek Status Connect System Operator’s Guide. If there is no connector, Siemens Healthcare Diagnostics recommends NOTE: setting the connector to Disabled setting. Setting the connector to Enabled setting without a connector may prevent communication with an external system. The IP address screen displays. 18. Enter the IP address and select Enter. Clinitek Status Connect System Operator’s Guide. The Enter WEP key screen displays. 4. Enter the WEP key. 5. Select Enter. Clinitek Status Connect System Operator’s Guide. To enter numeric text, select the 123. 9. Select Enter. 10. When you complete the settings, select Next. Clinitek Status Connect System Operator’s Guide. To print to an external printer, select External printer. 17. Select Done 3 times to return to the Select Ready screen. Clinitek Status Connect System Operator’s Guide. Before calling, please complete the Pre-service Checklist, below. Make a photocopy of the checklist first. This information helps your local technical support provider to identify the probable cause of the problem.

Clinitek Status Connect System Operator’s Guide. Is the bar code scanner working properly. Clinitek Status Connect System Operator’s Guide. Part Number Description 10376827 English Quick Reference Guide 10376828 Multi-language Documentation CD 10378409 Clinitek Status Connect System LIS Specification 10376829 Operator’s Guide (English) 10376830 Operator’s Guide (French) 10376831 Operator’s Guide (German) 10376839 Operator’s Guide (Italian) NOTE: Clinitek Status Connect System Operator’s Guide. This symbol identifies the location of a serial port. This symbol identifies the location of an Ethernet port. This symbol identifies the location of the USB port. Clinitek Status Connect System Operator’s Guide. This symbol indicates the revision letter of a part or product. This symbol indicates the name and location of the product manufacturer. This symbol indicates the date of manufacture of the product. Clinitek Status Connect System Operator’s Guide. Clinitek Status Connect System Operator’s Guide. There is no guarantee that interference will not occur in a particular installation. If the scanner does not consistently read your labels, apply a test label of the format being used to a new specimen tube and perform the Bar Code Test. If Clinitek Status Connect System Operator’s Guide. If the narrow bar width is at the Clinitek Status Connect System Operator’s Guide. Clinitek Status Connect System Operator’s Guide. The POCT1A protocol supports bidirectional communication to allow the system to send and receive information from an Clinitek Status Connect System Operator’s Guide. Otherwise, the records are deleted. The connector can also send CSV-formatted results to a host computer using the rear serial (RS-232) port. Clinitek Status Connect System Operator’s Guide. Term Definition Alert Message A message that conveys information about the system to the user. Alphanumeric Data comprised of alphabetic and numeric characters.

Audio Alert Sounds emitted by the system to draw the operator’s. Test Sequence A series of software UI screens that guides the operator through the tasks required to perform a test on a sample. Clinitek Status Connect System Operator’s Guide. You must have JavaScript enabled in your browser to utilize the functionality of this website. Warranties Extended manufacturer warranties on capital equipment. Terms and conditions apply. Use lists to build regular orders. FreeFax: 0800 8046448 Fax your official purchase order or use our downloadable order form. Or call us on freephone 0800 804 6447 to discuss your requirements. For non NHS businesses we provide credit facilities subject to status. Catalogue 2019 CATALOGUE Our new catalogue for 2019 is available now. Online Viewer Download PDF Get it FREE Order the print version.Together, these provide improved clinical information. Reviews Be the first to review this product Write Your Own Review Only registered users can write reviews. Please, log in or register Why buy from Medisave. Medisave supplies health professionals, business and home users. Send Question Question will be displayed after moderation. No questions yet. Be the first to ask the question. All Rights Reserved. Looking to buy Littmann Stethoscopes in the USA.You can pay on our website without re-entering your payment and address details. All Amazon transactions are protected by Amazon's A-to-z Guarantee.